| Assessment Year | 2008 |
|---|---|
| Principal Product | Large Diameter Pipe |
| NAICS | 331221: Rolled Steel Shape Manufacturing |
| SIC | 3317: Steel Pipe and Tubes |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
300,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 4,992
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $368,353 | 6,561,760 |
kWh
|
$0.056 |
| Electricity Demand | $48,996 | 20,883 |
kW-mo/yr
|
$2.35 |
| Electricity Fees | $46,308 | - |
|
- |
| Natural Gas | $189,757 | 17,360 |
MMBtu
|
$10.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $106,779 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4131: Size electric motors for peak operating efficiency | $46,153 | $56,500 |
$46,153
176,773
kWh
|
- | |
| 02 | 2.2151: Clean steam coils in processing tanks | $6,588 | $1,250 | - |
$6,588
-
MMBtu
|
|
| 03 | 2.4224: Upgrade controls on compressors | $43,923 | $7,200 |
$43,923
863,036
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $7,829 | $47,094 |
$7,829
102,474
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $2,286 | $1,850 |
$2,286
18,527
kWh
|
- | |
| TOTAL RECOMMENDED | $106,779 | $113,894 |
$100,191
1,160,810
kWh
|
$6,588
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs