| Assessment Year | 2001 |
|---|---|
| Principal Product | Business Forms |
| NAICS |
n/a
|
| SIC | 2764: |
| Sales Range | $10 M to 50M |
| # of Employees | 99 |
| Plant Area |
104,850
ft2
|
| Annual Production | 3,400,000
lb
|
| Production Hrs. Annual | 6,048
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,781 | 2,455,500 |
kWh
|
$0.037 |
| Electricity Demand | $48,289 | 5,953 |
kW-mo/yr
|
$8.11 |
| Natural Gas | $1,881 | 298 |
MMBtu
|
$6.31 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,446 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,397 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $6,177 | $2,016 | - |
$6,177
-
kW-mo/yr
|
- | - | |
| 02 | 3.6192: Use a less expensive method of waste removal | $3,272 | - | - | - |
$3,272
-
Tgal
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,184 | $1,049 |
$1,466
56,380
kWh
|
$1,718
-
kW-mo/yr
|
- | - | |
| 04 | 3.5316: Contract a wood pallet recycling company | $3,110 | - | - | - | - |
$3,110
-
gal
|
|
| 05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,912 | $4,110 | n/a |
$2,912
29,606
kWh
|
- | - | - |
| 06 | 2.7492: Use proper thickness of insulation on building envelope | $2,195 | $12,855 |
$2,195
84,413
kWh
|
- | - | - | |
| 07 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $838 | $624 | - | - |
$838
-
Tgal
|
- | |
| 08 | 2.7135: Install occupancy sensors | $470 | $175 |
$470
18,068
kWh
|
- | - | - | |
| 09 | 3.1191: Change procedures / equipment / operating conditions | $288 | - |
$288
3,902
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $22,446 | $20,829 |
$7,331
192,369
kWh
|
$7,895
-
kW-mo/yr
|
$4,110
-
Tgal
|
$3,110
-
gal
|
||
| TOTAL IMPLEMENTED | $13,397 | $2,640 | - |
$6,177
-
kW-mo/yr
|
$4,110
-
Tgal
|
$3,110
-
gal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs