| Assessment Year | 2005 |
|---|---|
| Principal Product | tempered glass (square feet) |
| NAICS | 327212: Other Pressed and Blown Glass and Glassware Manufacturing |
| SIC | 3231: Glass Products, Made of Purchased Glass |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
80,000
ft2
|
| Annual Production | 8,184,000
thousand feet
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $577,160 | 12,478,006 |
kWh
|
$0.046 |
| Electricity Demand | $257,576 | 479,172 |
kW-mo/yr
|
$0.54 |
| Electricity Fees | $30,163 | - |
|
- |
| Natural Gas | $11,110 | 1,308 |
MMBtu
|
$8.49 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $286,326 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,526 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.421: Modify current incentive program | $220,500 | $33,360 | - | - | $220,500 | - | |
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $60,800 | $101,000 |
$53,500
1,010,000
kWh
|
$7,300
-
kW-mo/yr
|
- | - | |
| 03 | 2.8112: Combine utility meters | $1,500 | $4,000 | - | - | - | $1,500 | |
| 04 | 2.4133: Use most efficient type of electric motors | $3,526 | - |
$2,975
56,796
kWh
|
$551
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $286,326 | $138,360 |
$56,475
1,066,796
kWh
|
$7,851
-
kW-mo/yr
|
$220,500 | $1,500 | ||
| TOTAL IMPLEMENTED | $3,526 | - |
$2,975
56,796
kWh
|
$551
-
kW-mo/yr
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs