ITAC Assessment: OR0452
ITAC logo
ITAC Assessment: OR0452
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Corrugated Cardboard
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 516,478
ft2
Annual Production 869,000,000
thousand feet
Production Hrs. Annual 6,600
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $238,437 5,677,080
kWh
Electricity Demand $47,231 10,933
kW-mo/yr
Electricity Fees $18,203 -
Natural Gas $250,311 51,539
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $124,535 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $118,600

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
01 4.625: Develop standard operating procedures $106,000 - - - - $106,000
02 2.4133: Use most efficient type of electric motors $6,280 $7,540 $5,040
120,000
kWh
$1,240
-
kW-mo/yr
- -
03 2.6218: Turn off equipment when not in use $2,335 $4,025 $2,335
60,700
kWh
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $900 $900 $900
20,000
kWh
- - -
05 2.4224: Upgrade controls on compressors $3,600 $4,000 $3,000
71,000
kWh
$600
-
kW-mo/yr
- -
06 2.2211: Use optimum temperature $5,420 $7,880 $880
107
kWh
- $4,540
-
MMBtu
-
TOTAL RECOMMENDED $124,535 $24,345 $12,155
271,807
kWh
$1,840
-
kW-mo/yr
$4,540
-
MMBtu
$106,000
TOTAL IMPLEMENTED $118,600 $16,320 $6,820
140,107
kWh
$1,240
-
kW-mo/yr
$4,540
-
MMBtu
$106,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs