Assessment Year | 2023 |
---|---|
Principal Product | Roofing; Pond Liners; Custom Products |
NAICS | 326299: All Other Rubber Product Manufacturing |
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
120,000
ft2
|
Annual Production | 9,598,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $389,107 | 2,529,775 |
kWh
|
$0.15 |
Electricity Demand | $362,519 | 9,168 |
kW-mo/yr
|
$39.54 |
Electricity Fees | $(-316,732.0) | - |
|
- |
Natural Gas | $97,675 | 12,439 |
MMBtu
|
$7.85 |
TOTAL YEARLY COSTS | $532,569 | |||
RECOMMENDED SAVINGS* | $165,840 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $132,467 | $665,395 |
$119,928
779,718
kWh
|
$12,539
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,014 | $7,324 |
$2,147
13,956
kWh
|
$2,867
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $798 | $2,977 |
$798
5,188
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $1,078 | $7,298 | - | - |
$1,078
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,647 | $23,000 |
$14,647
95,226
kWh
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,713 | $4,600 |
$2,713
17,637
kWh
|
- | - | |
07 | 2.2441: Preheat boiler makeup water with waste process heat | $8,791 | $39,456 | - | - |
$8,791
-
MMBtu
|
|
08 | 2.2136: Install / repair insulation on steam lines | $332 | $1,762 | - | - |
$332
-
MMBtu
|
|
TOTAL RECOMMENDED | $165,840 | $751,812 |
$140,233
911,725
kWh
|
$15,406
-
kW-mo/yr
|
$10,201
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs