Assessment Year | 2003 |
---|---|
Principal Product | Dimensional Lumber |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | n/a |
# of Employees | 0 |
Plant Area |
n/a
|
Annual Production | 0
thousand feet
|
Production Hrs. Annual | 2,448
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,229 | 3,326,600 |
kWh
|
$0.055 |
Electricity Demand | $38,029 | 13,447 |
kW-mo/yr
|
$2.83 |
Electricity Fees | $3,149 | - |
|
- |
LPG | $88,200 | 8,070 |
MMBtu
|
$10.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,570 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,860 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $7,000 | $580 |
$5,600
102,000
kWh
|
$1,400
-
kW-mo/yr
|
- | - | - | |
02 | 2.4224: Upgrade controls on compressors | $3,700 | $2,000 |
$3,700
66,000
kWh
|
- | - | - | - | |
03 | 2.7124: Make a practice of turning off lights when not needed | $11,950 | $880 |
$9,200
166,000
kWh
|
- | - | - | $2,750 | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,000 | $150 | - | - |
$3,300
-
MMBtu
|
$(-300.0) | - | |
05 | 2.2136: Install / repair insulation on steam lines | $9,910 | $14,200 |
$9,910
180,000
kWh
|
- | - | - | - | |
06 | 2.4133: Use most efficient type of electric motors | $12,200 | $24,350 |
$9,150
164,450
kWh
|
$3,050
-
kW-mo/yr
|
- | - | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $810 | - |
$630
11,300
kWh
|
$180
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $48,570 | $42,160 |
$38,190
689,750
kWh
|
$4,630
-
kW-mo/yr
|
$3,300
-
MMBtu
|
$(-300.0) | $2,750 | ||
TOTAL IMPLEMENTED | $31,860 | $15,810 |
$24,710
448,000
kWh
|
$1,400
-
kW-mo/yr
|
$3,300
-
MMBtu
|
$(-300.0) | $2,750 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs