Assessment Year | 2003 |
---|---|
Principal Product | Architectural Concrete |
NAICS | 327390: Other Concrete Product Manufacturing |
SIC | 3272: Concrete Products, Except Block and Brick |
Sales Range | $10 M to 50M |
# of Employees | 49 |
Plant Area |
n/a
|
Annual Production | 5,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $847,834 | 24,349,051 |
kWh
|
$0.035 |
Electricity Demand | $153,966 | 45,024 |
kW-mo/yr
|
$3.42 |
Electricity Fees | $41,200 | - |
|
- |
Natural Gas | $564,896 | 128,003 |
MMBtu
|
$4.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $100,721 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $63,131 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.621: Use fixtures to reduce machine changeout times | $44,700 | $32,500 | - | - | - | $44,700 | - | - | |
02 | 3.1182: Make a new by-product | $33,850 | $85,000 | n/a |
$(-185.0)
(-3,410)
kWh
|
$(-1,815.0)
-
kW-mo/yr
|
- | $(-3,150.0) | $39,000 | - |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,740 | $1,070 |
$3,200
57,000
kWh
|
$850
-
kW-mo/yr
|
- | $(-150.0) | - | $(-160.0) | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,300 | $18,600 |
$7,410
134,000
kWh
|
$1,890
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,780 | $150 | - | - |
$5,080
-
MMBtu
|
$(-300.0) | - | - | |
06 | 2.6218: Turn off equipment when not in use | $3,400 | $210 |
$3,400
60,700
kWh
|
- | - | - | - | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $450 | - |
$350
6,300
kWh
|
$100
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $501 | - |
$389
7,060
kWh
|
$112
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $100,721 | $137,530 |
$14,564
261,650
kWh
|
$1,137
-
kW-mo/yr
|
$5,080
-
MMBtu
|
$41,100 | $39,000 | $(-160.0) | ||
TOTAL IMPLEMENTED | $63,131 | $51,460 |
$11,549
208,060
kWh
|
$2,102
-
kW-mo/yr
|
$5,080
-
MMBtu
|
$44,400 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs