Assessment Year | 2001 |
---|---|
Principal Product | Steel Castings |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
75,000
ft2
|
Annual Production | 2,500,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,538 | 7,188,140 |
kWh
|
$0.021 |
Electricity Demand | $87,685 | 27,192 |
kW-mo/yr
|
$3.22 |
Electricity Fees | $20,968 | - |
|
- |
Natural Gas | $292,059 | 38,366 |
MMBtu
|
$7.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,355 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,700 | $5,500 |
$4,600
171,300
kWh
|
$1,100
-
kW-mo/yr
|
- | |
02 | 2.4224: Upgrade controls on compressors | $9,700 | $18,800 |
$7,000
260,800
kWh
|
$2,700
-
kW-mo/yr
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $6,600 | $15,463 |
$5,300
197,541
kWh
|
$1,300
-
kW-mo/yr
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $1,929 | $1,568 |
$1,516
56,599
kWh
|
$413
-
kW-mo/yr
|
- | |
05 | 2.3212: Optimize plant power factor | $2,426 | $4,000 | - | - | $2,426 | |
TOTAL RECOMMENDED | $26,355 | $45,331 |
$18,416
686,240
kWh
|
$5,513
-
kW-mo/yr
|
$2,426 | ||
TOTAL IMPLEMENTED | $17,329 | $25,868 |
$13,116
488,699
kWh
|
$4,213
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs