ITAC Assessment: OR0384
ITAC logo
ITAC Assessment: OR0384
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product Hardwood Veneer
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $1
M
to 5
M
# of Employees 35
Plant Area 10,000
ft2
Annual Production 68,550
ton
Production Hrs. Annual 4,856
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $69,819 2,032,532
kWh
Electricity Demand $19,540 72,372
kW-mo/yr
Electricity Fees $3,442 -
LPG $3,905 383
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $157,068 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,547

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
01 4.111: Add equipment/ operators to reduce production bottleneck $138,600 $385,000 - - - $(-121,400.0) - $260,000
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $543 $500 $445
12,896
kWh
$98
-
kW-mo/yr
- - - -
03 2.4224: Upgrade controls on compressors $6,605 $13,210 $5,455
157,386
kWh
$1,150
-
kW-mo/yr
- - - -
04 2.3212: Optimize plant power factor $3,240 $9,000 - - $3,240 - - -
05 2.7124: Make a practice of turning off lights when not needed $2,316 - $1,714
49,531
kWh
- - $135 $467 -
06 2.4133: Use most efficient type of electric motors $5,764 $24,310 $4,415
127,491
kWh
$1,349
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $157,068 $432,020 $12,029
347,304
kWh
$2,597
-
kW-mo/yr
$3,240 $(-121,265.0) $467 $260,000
TOTAL IMPLEMENTED $9,547 $33,810 $4,860
140,387
kWh
$1,447
-
kW-mo/yr
$3,240 - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs