Assessment Year | 1999 |
---|---|
Principal Product | Travel Trailers |
NAICS |
n/a
|
SIC | 3792: Travel Trailers and Campers |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
67,000
ft2
|
Annual Production | 765
pieces
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $22,037 | 868,992 |
kWh
|
$0.025 |
Electricity Demand | $15,377 | 44,208 |
kW-mo/yr
|
$0.35 |
Electricity Fees | $745 | - |
|
- |
Natural Gas | $23,102 | 4,053 |
MMBtu
|
$5.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,119,267 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,492 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.423: Move product using mechanical means | $5,106,400 | $556,000 | - | - | - | - | - | - | $5,106,400 | |
02 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $6,650 | $24,750 |
$(-20.0)
(-879)
kWh
|
$(-690.0)
-
kW-mo/yr
|
- |
$7,360
-
lb
|
- | - | - | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,080 | $13,800 |
$2,340
106,975
kWh
|
$740
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.6218: Turn off equipment when not in use | $178 | - |
$145
6,741
kWh
|
- | - | - | $15 | $18 | - | |
05 | 2.2437: Recover waste heat from equipment | $730 | $381 | - | - |
$730
-
MMBtu
|
- | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $254 | $1,000 |
$118
5,569
kWh
|
$136
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4224: Upgrade controls on compressors | $1,508 | $1,454 |
$701
32,239
kWh
|
$807
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $467 | $441 |
$225
10,258
kWh
|
$242
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $5,119,267 | $597,826 |
$3,509
160,903
kWh
|
$1,235
-
kW-mo/yr
|
$730
-
MMBtu
|
$7,360
-
lb
|
$15 | $18 | $5,106,400 | ||
TOTAL IMPLEMENTED | $11,492 | $41,004 |
$3,139
143,904
kWh
|
$993
-
kW-mo/yr
|
- |
$7,360
-
lb
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs