Assessment Year | 1998 |
---|---|
Principal Product | Cookies |
NAICS |
n/a
|
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
110,000
ft2
|
Annual Production | 25,289,628
lb
|
Production Hrs. Annual | 7,514
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $132,992 | 3,906,800 |
kWh
|
$0.034 |
Electricity Demand | $31,532 | 86,784 |
kW-mo/yr
|
$0.36 |
Electricity Fees | $1,780 | - |
|
- |
Natural Gas | $179,665 | 44,915 |
MMBtu
|
$4.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $233,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $195,044 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.521: Clear and rent existing space | $176,000 | $200,000 | - | - | - |
$176,000
-
lb
|
- | - | - | - | - | |
02 | 4.126: Install sensors to detect defects | $20,040 | $2,745 | - | - | - | - | $1,725 | - | - | - | $18,315 | |
03 | 4.631: Install an uninteruptable power supply | $13,651 | $22,265 | - | - | - | - | - | - | - | - | $13,651 | |
04 | 4.423: Move product using mechanical means | $12,158 | $28,400 |
$(-201.0)
(-5,862)
kWh
|
$(-41.0)
-
kW-mo/yr
|
- | - | $12,400 | - | - | - | - | |
05 | 3.1194: Use automatic flow control | $1,896 | $1,300 | - | - | - | - | - | - | $1,896 | - | - | |
06 | 4.821: Pay bills on time to avoid late fees | $986 | - | - | - | - | - | - | $986 | - | - | - | |
07 | 4.431: Train operators for maximum operating efficiency | $577 | $411 | - | - | - | - | $577 | - | - | - | - | |
08 | 2.7134: Use photocell controls | $1,460 | $500 |
$1,051
30,774
kWh
|
- | - | - | $194 | - | - | $215 | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,863 | - |
$3,205
94,080
kWh
|
$658
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
10 | 2.3212: Optimize plant power factor | $1,680 | $11,200 | - | - | $1,680 | - | - | - | - | - | - | |
11 | 2.4224: Upgrade controls on compressors | $882 | $1,210 |
$735
21,688
kWh
|
$147
-
kW-mo/yr
|
- | - | - | - | - | - | - | |
TOTAL RECOMMENDED | $233,193 | $268,031 |
$4,790
140,680
kWh
|
$764
-
kW-mo/yr
|
$1,680 |
$176,000
-
lb
|
$14,896 | $986 | $1,896 | $215 | $31,966 | ||
TOTAL IMPLEMENTED | $195,044 | $229,311 |
$4,055
118,992
kWh
|
$617
-
kW-mo/yr
|
- |
$176,000
-
lb
|
$13,171 | $986 | - | $215 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs