Assessment Year 1998
Principal Product Extruded Plastic
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 103,240
ft2
Annual Production 7,527,341
lb
Production Hrs. Annual 7,344
hrs
Location (State) Washington

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $104,081 4,864,889
kWh
Electricity Demand $47,675 185,832
kW-mo/yr
Electricity Fees $21,928 -
Natural Gas $3,374 671
MMBtu
LPG $6,074 768
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $166,991 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,872

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.3212: Optimize plant power factor $25,112 - - - $25,112 - -
02 2.7124: Make a practice of turning off lights when not needed $3,076 - $2,109
98,476
kWh
- - $81 $886
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,078 $7,300 $897
41,911
kWh
$181
-
kW-mo/yr
- - -
04 2.4133: Use most efficient type of electric motors $2,009 $9,609 $1,360
63,599
kWh
$649
-
kW-mo/yr
- - -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $857 - $554
25,791
kWh
$303
-
kW-mo/yr
- - -
06 2.6231: Utilize controls to operate equipment only when needed $27,785 - $23,373
1,092,614
kWh
$4,412
-
kW-mo/yr
- - -
07 4.441: Install automatic packing equipment $94,439 $150,000 $(-1,657.0)
(-77,374)
kWh
- - $96,096 -
08 2.4237: Substitute compressed air cooling with water or air cooling $5,087 $6,000 $6,124
286,342
kWh
$(-1,037.0)
-
kW-mo/yr
- - -
09 2.2628: Utilize a less expensive cooling method $1,387 - $1,387
64,771
kWh
- - - -
10 2.2511: Insulate bare equipment $6,161 $217 $6,161
288,101
kWh
- - - -
TOTAL RECOMMENDED $166,991 $173,126 $40,308
1,884,231
kWh
$4,508
-
kW-mo/yr
$25,112 $96,177 $886
TOTAL IMPLEMENTED $30,872 $16,909 $25,630
1,198,124
kWh
$5,242
-
kW-mo/yr
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs