Assessment Year | 1998 |
---|---|
Principal Product | Extruded Plastic |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
103,240
ft2
|
Annual Production | 7,527,341
lb
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $104,081 | 4,864,889 |
kWh
|
$0.021 |
Electricity Demand | $47,675 | 185,832 |
kW-mo/yr
|
$0.26 |
Electricity Fees | $21,928 | - |
|
- |
Natural Gas | $3,374 | 671 |
MMBtu
|
$5.03 |
LPG | $6,074 | 768 |
MMBtu
|
$7.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $166,991 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,872 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $25,112 | - | - | - | $25,112 | - | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $3,076 | - |
$2,109
98,476
kWh
|
- | - | $81 | $886 | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,078 | $7,300 |
$897
41,911
kWh
|
$181
-
kW-mo/yr
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $2,009 | $9,609 |
$1,360
63,599
kWh
|
$649
-
kW-mo/yr
|
- | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $857 | - |
$554
25,791
kWh
|
$303
-
kW-mo/yr
|
- | - | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $27,785 | - |
$23,373
1,092,614
kWh
|
$4,412
-
kW-mo/yr
|
- | - | - | |
07 | 4.441: Install automatic packing equipment | $94,439 | $150,000 |
$(-1,657.0)
(-77,374)
kWh
|
- | - | $96,096 | - | |
08 | 2.4237: Substitute compressed air cooling with water or air cooling | $5,087 | $6,000 |
$6,124
286,342
kWh
|
$(-1,037.0)
-
kW-mo/yr
|
- | - | - | |
09 | 2.2628: Utilize a less expensive cooling method | $1,387 | - |
$1,387
64,771
kWh
|
- | - | - | - | |
10 | 2.2511: Insulate bare equipment | $6,161 | $217 |
$6,161
288,101
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $166,991 | $173,126 |
$40,308
1,884,231
kWh
|
$4,508
-
kW-mo/yr
|
$25,112 | $96,177 | $886 | ||
TOTAL IMPLEMENTED | $30,872 | $16,909 |
$25,630
1,198,124
kWh
|
$5,242
-
kW-mo/yr
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs