Assessment Year | 1997 |
---|---|
Principal Product | Mineral Wool |
NAICS |
n/a
|
SIC | 3296: Mineral Wool |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
35,000
ft2
|
Annual Production | 19,919
ton
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $171,696 | 8,025,498 |
kWh
|
$0.021 |
Electricity Demand | $86,013 | 232,992 |
kW-mo/yr
|
$0.37 |
Electricity Fees | $8,237 | - |
|
- |
Natural Gas | $149,347 | 41,043 |
MMBtu
|
$3.64 |
Other Energy | $889,224 | 110,600 |
MMBtu
|
$8.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $173,751 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,821 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Energy Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.3127: Use adsorption, ion exchange to remove contaminants | $20,180 | $2,500 | - | - | - | - | - | - | - | $(-280.0) | - | $20,460 | |
02 | 3.1191: Change procedures / equipment / operating conditions | $45,520 | $74,000 | - | - | - | - |
$360
-
MMBtu
|
$7,025
-
lb
|
- | - | $38,135 | - | |
03 | 3.1191: Change procedures / equipment / operating conditions | $31,298 | $34,800 | - | - | - | - |
$248
-
MMBtu
|
$4,830
-
lb
|
- | - | $26,220 | - | |
04 | 3.1191: Change procedures / equipment / operating conditions | $27,796 | $8,400 | - | - | - | - |
$96
-
MMBtu
|
- | $4,590 | - | $10,010 | $13,100 | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $23,300 | $104,000 | - | - | - |
$23,300
-
MMBtu
|
- | - | - | - | - | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $3,230 | $9,400 |
$1,800
84,115
kWh
|
$1,430
-
kW-mo/yr
|
- | - | - | - | - | - | - | - | |
07 | 2.3212: Optimize plant power factor | $7,222 | $16,000 | - | - | $7,222 | - | - | - | - | - | - | - | |
08 | 2.4133: Use most efficient type of electric motors | $6,369 | $13,594 |
$4,470
208,968
kWh
|
$1,899
-
kW-mo/yr
|
- | - | - | - | - | - | - | - | |
09 | 2.4226: Use / purchase optimum sized compressor | $6,104 | $26,180 |
$4,483
209,555
kWh
|
$1,621
-
kW-mo/yr
|
- | - | - | - | - | - | - | - | |
10 | 2.7124: Make a practice of turning off lights when not needed | $2,732 | - |
$1,566
73,271
kWh
|
- | - | - | - | - | $144 | - | - | $1,022 | |
TOTAL RECOMMENDED | $173,751 | $288,874 |
$12,319
575,909
kWh
|
$4,950
-
kW-mo/yr
|
$7,222 |
$23,300
-
MMBtu
|
$704
-
MMBtu
|
$11,855
-
lb
|
$4,734 | $(-280.0) | $74,365 | $34,582 | ||
TOTAL IMPLEMENTED | $16,821 | $38,994 |
$6,270
293,083
kWh
|
$3,329
-
kW-mo/yr
|
$7,222 | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Energy Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |