Assessment Year | 1995 |
---|---|
Principal Product | Raw Dimensional |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $50 M to 100M |
# of Employees | 105 |
Plant Area |
207,500
ft2
|
Annual Production | 106,000
thousand feet
|
Production Hrs. Annual | 3,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $458,166 | 9,181,126 |
kWh
|
$0.050 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,607 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $80,203 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $75,256 | $4,923 |
$75,256
1,600,821
kWh
|
|
02 | 2.4224: Upgrade controls on compressors | $9,910 | $1,200 |
$9,910
250,586
kWh
|
|
03 | 2.4239: Eliminate or reduce compressed air usage | $2,778 | $200 |
$2,778
70,633
kWh
|
|
04 | 2.7124: Make a practice of turning off lights when not needed | $4,671 | - |
$4,671
118,699
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,258 | $3,360 |
$1,258
24,033
kWh
|
|
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,823 | $37,075 |
$7,823
147,714
kWh
|
|
07 | 2.4133: Use most efficient type of electric motors | $911 | $4,478 |
$911
16,706
kWh
|
|
TOTAL RECOMMENDED | $102,607 | $51,236 |
$102,607
2,229,192
kWh
|
||
TOTAL IMPLEMENTED | $80,203 | $12,961 |
$80,203
1,712,193
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs