Assessment Year | 1993 |
---|---|
Principal Product | Dimensional Lumber |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 29,515,000
thousand feet
|
Production Hrs. Annual | 3,372
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,249 | 2,898,007 |
kWh
|
$0.034 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,519 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $2,146 | - |
$2,146
98,476
kWh
|
|
02 | 2.6218: Turn off equipment when not in use | $538 | $410 |
$538
24,619
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,049 | $1,100 |
$1,049
37,808
kWh
|
|
04 | 2.6231: Utilize controls to operate equipment only when needed | $1,840 | $11,200 |
$1,840
84,408
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $127 | $240 |
$127
4,396
kWh
|
|
06 | 2.6218: Turn off equipment when not in use | $636 | - |
$636
29,308
kWh
|
|
07 | 2.4133: Use most efficient type of electric motors | $144 | $604 |
$144
4,396
kWh
|
|
08 | 2.3212: Optimize plant power factor | $3,039 | $5,250 |
$3,039
-
kWh
|
|
TOTAL RECOMMENDED | $9,519 | $18,804 |
$9,519
283,411
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs