Assessment Year | 1991 |
---|---|
Principal Product | HARDWOOD PLYWOOD |
NAICS |
n/a
|
SIC | 2435: Hardwood Veneer and Plywood |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 6,000
thousand feet
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,599 | 2,324,150 |
kWh
|
$0.050 |
Natural Gas | $7,020 | 1,377 |
MMBtu
|
$5.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,396 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $1,058 | - |
$1,058
20,809
kWh
|
- | - | |
02 | 2.6232: Install set-back timers | $486 | - |
$486
7,620
kWh
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $60 | $78 |
$60
1,172
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $181 | - |
$202
4,396
kWh
|
- | $(-21.0) | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $12,611 | - |
$21,241
319,461
kWh
|
$(-8,630.0)
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $14,396 | $78 |
$23,047
353,458
kWh
|
$(-8,630.0)
-
MMBtu
|
$(-21.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs