Assessment Year | 1990 |
---|---|
Principal Product | IRRIGATION EQUIPMENT |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $118,236 | 3,720,985 |
kWh
|
$0.032 |
Natural Gas | $52,724 | 13,591 |
MMBtu
|
$3.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,199 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.4131: Size electric motors for peak operating efficiency | $1,019 | $548 |
$1,019
34,584
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $934 | $1,451 |
$433
14,361
kWh
|
$501 | |
03 | 2.4221: Install compressor air intakes in coolest locations | $95 | - |
$95
2,638
kWh
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $38,901 | $50,000 |
$2,181
59,496
kWh
|
$36,720 | |
05 | 2.4133: Use most efficient type of electric motors | $250 | $744 |
$250
8,206
kWh
|
- | |
TOTAL RECOMMENDED | $41,199 | $52,743 |
$3,978
119,285
kWh
|
$37,221 | ||
TOTAL IMPLEMENTED | $40,180 | $52,195 |
$2,959
84,701
kWh
|
$37,221 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs