| Assessment Year | 2016 |
|---|---|
| Principal Product | SYP Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $50 M to 100M |
| # of Employees | 135 |
| Plant Area |
241,500
ft2
|
| Annual Production | 220
units
|
| Production Hrs. Annual | 4,990
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $786,599 | 20,764,800 |
kWh
|
$0.038 | |
| Electricity Demand | $328,909 | 44,329 |
kW-mo/yr
|
$7.42 | |
| Waste Disposal Costs | |||||
| Water Usage | $12,261 | 6,897 |
Tgal
|
$1.78 | |
| TOTAL YEARLY COSTS | $1,127,769 | ||||
| RECOMMENDED SAVINGS* | $120,451 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $61,689 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $39,072 | $32,000 |
$39,072
1,028,321
kWh
|
- | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $29,900 | $37,940 |
$20,343
535,409
kWh
|
$9,557
-
kW-mo/yr
|
- | |
| 03 | 2.4312: Improve lubrication practices | $7,312 | - |
$6,990
183,937
kWh
|
$3,282
-
kW-mo/yr
|
$(-2,960.0) | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,021 | $29,085 |
$8,216
216,216
kWh
|
$2,805
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,284 | $6,222 |
$955
25,122
kWh
|
$329
-
kW-mo/yr
|
- | |
| 06 | 2.3212: Optimize plant power factor | $21,399 | $82,500 | - | - | $21,399 | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,312 | - |
$16,762
441,116
kWh
|
- | $(-6,450.0) | |
| 08 | 2.6232: Install set-back timers | $151 | $160 |
$151
3,973
kWh
|
- | - | |
| TOTAL RECOMMENDED | $120,451 | $187,907 |
$92,489
2,434,094
kWh
|
$15,973
-
kW-mo/yr
|
$11,989 | ||
| TOTAL IMPLEMENTED | $61,689 | $67,307 |
$65,005
1,710,775
kWh
|
$3,134
-
kW-mo/yr
|
$(-6,450.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs