Assessment Year | 1999 |
---|---|
Principal Product | Office partition paneling fabric |
NAICS |
n/a
|
SIC | 2399: Fabricated Textile Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
98,000
ft2
|
Annual Production | 1,500
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $161,814 | 5,368,699 |
kWh
|
$0.030 |
Electricity Demand | $90,904 | 10,790 |
kW-mo/yr
|
$8.42 |
Electricity Fees | $7,856 | - |
|
- |
Natural Gas | $427,633 | 85,272 |
MMBtu
|
$5.01 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $276,922 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $43,536 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1133: Adjust burners for efficient operation | $1,107 | $800 | - | - |
$607
-
MMBtu
|
- | - | $500 | - | - | |
02 | 2.1133: Adjust burners for efficient operation | $35,782 | $800 | - | - |
$35,782
-
MMBtu
|
- | - | - | - | - | |
03 | 2.2437: Recover waste heat from equipment | $4,918 | $4,000 | - | - |
$4,918
-
MMBtu
|
- | - | - | - | - | |
04 | 2.2511: Insulate bare equipment | $877 | $300 | - | - |
$877
-
MMBtu
|
- | - | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $852 | $10 |
$548
18,171
kWh
|
$304
-
kW-mo/yr
|
- | - | - | - | - | - | |
06 | 3.5313: Increase amount of waste recovered for resale | $213 | $400 | - | - | - |
$213
-
lb
|
- | - | - | - | |
07 | 4.122: Develop standard procedures to improve internal yields | $90,000 | $7,500 | - | - | - | - | - | - | - | $90,000 | |
08 | 4.125: | $143,173 | $137,600 | - | - |
$48,333
-
MMBtu
|
- | $57,240 | - |
$37,600
-
Tgal
|
- | |
TOTAL RECOMMENDED | $276,922 | $151,410 |
$548
18,171
kWh
|
$304
-
kW-mo/yr
|
$90,517
-
MMBtu
|
$213
-
lb
|
$57,240 | $500 |
$37,600
-
Tgal
|
$90,000 | ||
TOTAL IMPLEMENTED | $43,536 | $5,910 |
$548
18,171
kWh
|
$304
-
kW-mo/yr
|
$42,184
-
MMBtu
|
- | - | $500 | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Water Consumption Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs