ITAC Assessment: OK1150
ITAC logo
ITAC Assessment: OK1150
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Air Conditioner Components
NAICS 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area 45,500
ft2
Annual Production 100,000
units
Production Hrs. Annual 2,080
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $135,056 2,250,927
kWh
Electricity Demand $62,222 6,100
kW-mo/yr
Natural Gas $10,574 2,250
MMBtu
Waste Disposal Costs
Water Usage $15,202 4,310
Tgal
Water Disposal $32,294 4,310
Tgal
TOTAL YEARLY COSTS $255,348
RECOMMENDED SAVINGS* $29,651 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,079 $4,144 $1,049
17,481
kWh
$1,030
-
kW-mo/yr
-
02 2.9114: Use solar heat to make electricty $21,879 $215,280 $21,879
364,643
kWh
- -
03 2.7261: Install timers and/or thermostats $2,139 $3,510 - - $2,139
-
MMBtu
04 2.4231: Reduce the pressure of compressed air to the minimum required $670 - $670
11,172
kWh
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,376 $5,473 $2,376
39,603
kWh
- -
06 2.6211: Conserve energy by efficient use of vending machines $508 $570 $508
8,462
kWh
- -
TOTAL RECOMMENDED $29,651 $228,977 $26,482
441,361
kWh
$1,030
-
kW-mo/yr
$2,139
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs