Assessment Year | 2025 |
---|---|
Principal Product | Air conditioner coils |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
140,000
ft2
|
Annual Production | 118,000
units
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $93,804 | 1,563,396 |
kWh
|
$0.060 | |
Electricity Demand | $41,481 | 4,067 |
kW-mo/yr
|
$10.20 | |
Natural Gas | $12,332 | 2,609 |
MMBtu
|
$4.73 | |
Waste Disposal Costs | |||||
Water Usage | $4,636 | 1,159 |
Tgal
|
$4.00 | |
Water Disposal | $5,795 | 1,159 |
Tgal
|
$5.00 | |
TOTAL YEARLY COSTS | $158,048 | ||||
RECOMMENDED SAVINGS* | $53,276 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,841 | $7,919 |
$3,474
57,906
kWh
|
$1,367
-
kW-mo/yr
|
- | |
02 | 2.9114: Use solar heat to make electricty | $15,220 | $149,760 |
$15,220
253,667
kWh
|
- | - | |
03 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,628 | $4,560 |
$1,628
27,125
kWh
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $2,838 | $4,680 | - | - |
$2,838
-
MMBtu
|
|
05 | 2.7226: Use computer programs to optimize hvac performance | $22,422 | $158,900 |
$22,422
373,706
kWh
|
- | - | |
06 | 2.7231: Use radiant heater for spot heating | $5,142 | $15,536 | - | - |
$5,142
-
MMBtu
|
|
07 | 2.6211: Conserve energy by efficient use of vending machines | $1,185 | $1,330 |
$1,185
19,745
kWh
|
- | - | |
TOTAL RECOMMENDED | $53,276 | $342,685 |
$43,929
732,149
kWh
|
$1,367
-
kW-mo/yr
|
$7,980
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs