Assessment Year | 1989 |
---|---|
Principal Product | CANNED & DRY PET FOOD |
NAICS |
n/a
|
SIC | 2047: Dog and Cat Food |
Sales Range | $10 M to 50M |
# of Employees | 327 |
Plant Area |
n/a
|
Annual Production | 285,800
lb
|
Production Hrs. Annual | 7,920
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $843,114 | 18,521,982 |
kWh
|
$0.046 |
Natural Gas | $278,428 | 88,284 |
MMBtu
|
$3.15 |
Other Energy | $594,024 | 136,985 |
MMBtu
|
$4.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $136,862 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $80,702 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,054 | $500 |
$2,054
45,135
kWh
|
- | - | - | |
02 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $1,242 | $300 | - |
$1,242
-
MMBtu
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $8,858 | $7,838 |
$8,858
194,607
kWh
|
- | - | - | |
04 | 3.4115: Recover and reuse cooling water | $8,336 | $6,000 |
$200
4,396
kWh
|
- | - | $8,136 | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $36,912 | $32,650 |
$36,912
810,961
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,254 | $250 |
$1,254
27,550
kWh
|
- | - | - | |
07 | 2.2135: Repair and eliminate steam leaks | $18,354 | $3,000 | - | - |
$18,354
-
MMBtu
|
- | |
08 | 2.1392: Replace purchased steam with other energy source | $59,852 | - |
$494
10,844
kWh
|
- |
$59,358
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $136,862 | $50,538 |
$49,772
1,093,493
kWh
|
$1,242
-
MMBtu
|
$77,712
-
MMBtu
|
$8,136 | ||
TOTAL IMPLEMENTED | $80,702 | $3,550 |
$1,748
38,394
kWh
|
$1,242
-
MMBtu
|
$77,712
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs