ITAC Assessment: OK0021
ITAC logo
ITAC Assessment: OK0021
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1982
Principal Product ROASTED COFFEE AND TEA
NAICS
n/a
SIC 2095: Roasted Coffee
Sales Range $50
M
to 100
M
# of Employees 125
Plant Area
n/a
Annual Production 20,000,000
lb
Production Hrs. Annual 0
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $58,501 1,615,182
kWh
Natural Gas $55,047 24,962
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,510 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $266

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $417 $225 - $417
-
MMBtu
02 2.1233: Analyze flue gas for proper air/fuel ratio $5,873 $1,425 - $5,873
-
MMBtu
03 2.2424: Use heat in flue gases to preheat products or materials $3,426 $24,000 - $3,426
-
MMBtu
04 2.6218: Turn off equipment when not in use $12,842 - - $12,842
-
MMBtu
05 2.2424: Use heat in flue gases to preheat products or materials $6,552 $6,300 - $6,552
-
MMBtu
06 2.7226: Use computer programs to optimize hvac performance $3,950 $1,500 $3,950
108,734
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $266 $4,572 $266
7,327
kWh
-
09 2.4133: Use most efficient type of electric motors $3,184 $8,662 $3,184
87,925
kWh
-
TOTAL RECOMMENDED $36,510 $46,684 $7,400
203,986
kWh
$29,110
-
MMBtu
TOTAL IMPLEMENTED $266 $4,572 $266
7,327
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs