ITAC Assessment: OK1132
ITAC logo
ITAC Assessment: OK1132
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Waste water
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $1
M
to 5
M
# of Employees 7
Plant Area 29,350
ft2
Annual Production 654,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $382,553 5,835,660
kWh
Electricity Demand $132,145 12,332
kW-mo/yr
TOTAL YEARLY COSTS $514,698
RECOMMENDED SAVINGS* $66,458 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.9114: Use solar heat to make electricty $45,986 $421,200 $45,986
696,757
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,493 $4,158 $2,493
37,774
kWh
-
03 2.4156: Establish a preventative maintenance program $7,784 $4,200 $7,784
117,945
kWh
-
04 2.3212: Optimize plant power factor $10,195 $4,264 - $10,195
-
kW-mo/yr
TOTAL RECOMMENDED $66,458 $433,822 $56,263
852,476
kWh
$10,195
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs