Assessment Year | 2024 |
---|---|
Principal Product | Water treatment |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $500 k to 1M |
# of Employees | 7 |
Plant Area |
8,400
ft2
|
Annual Production | 87,600,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $226,769 | 1,919,817 |
kWh
|
$0.12 |
TOTAL YEARLY COSTS | $226,769 | |||
RECOMMENDED SAVINGS* | $38,565 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $197 | $1,095 |
$197
1,671
kWh
|
|
02 | 2.9114: Use solar heat to make electricty | $24,450 | $138,510 |
$24,450
207,204
kWh
|
|
03 | 2.4156: Establish a preventative maintenance program | $13,918 | $4,200 |
$13,918
117,945
kWh
|
|
TOTAL RECOMMENDED | $38,565 | $143,805 |
$38,565
326,820
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs