Assessment Year | 2025 |
---|---|
Principal Product | Aluminum Extrusion and Aluminum Doors |
NAICS | 331318: Other Aluminum Rolling, Drawing, and Extruding |
SIC | 3354: Aluminum Extruded Products |
Sales Range | $10 M to 50M |
# of Employees | 168 |
Plant Area |
90,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $226,722 | 2,023,771 |
kWh
|
$0.11 | |
Electricity Demand | $249,872 | 6,098 |
kW-mo/yr
|
$40.98 | |
Electricity Fees | $37,287 | - |
|
- | |
Natural Gas | $54,575 | 5,014 |
MMBtu
|
$10.88 | |
Other Gas | $7,685 | 1 |
MMBtu
|
$7,685.00 | |
Waste Disposal Costs | |||||
Water Usage | $9,892 | 1,359,864 |
Tgal
|
$0.007 | |
Other Liquid (non-haz) | $5,616 | 1 |
gal
|
$5,616.00 | |
TOTAL YEARLY COSTS | $591,649 | ||||
RECOMMENDED SAVINGS* | $547,981 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $178,607 | $160,000 |
$86,894
775,840
kWh
|
$91,713
-
kW-mo/yr
|
- | |
02 | 4.212: Adopt in-house material generation | $173,671 | $246,000 |
$(-25,590.0)
(-228,487)
kWh
|
- | $199,261 | |
03 | 2.9114: Use solar heat to make electricty | $83,244 | $844,770 |
$50,378
449,806
kWh
|
$32,866
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $63,388 | $5,500 |
$37,762
337,164
kWh
|
$25,626
-
kW-mo/yr
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $24,625 | $6,460 |
$11,974
106,912
kWh
|
$12,651
-
kW-mo/yr
|
- | |
06 | 2.4239: Eliminate or reduce compressed air usage | $9,124 | $500 |
$9,124
81,463
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,158 | $32,500 |
$8,158
36,045
kWh
|
- | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,048 | $25 |
$5,048
45,076
kWh
|
- | - | |
09 | 2.7135: Install occupancy sensors | $2,116 | $4,650 |
$1,087
9,709
kWh
|
$1,029
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $547,981 | $1,300,405 |
$184,835
1,613,528
kWh
|
$163,885
-
kW-mo/yr
|
$199,261 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs