Assessment Year | 2023 |
---|---|
Principal Product | Aircraft Refurbishment & Parts Manufacturing |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 132 |
Plant Area |
98,000
ft2
|
Annual Production | 600
ton
|
Production Hrs. Annual | 7,696
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $299,937 | 5,998,732 |
kWh
|
$0.050 | |
Electricity Demand | $315,973 | 14,382 |
kW-mo/yr
|
$21.97 | |
Electricity Fees | $21,914 | - |
|
- | |
Natural Gas | $58,838 | 6,348 |
MMBtu
|
$9.27 | |
Waste Disposal Costs | |||||
Water Usage | $50,603 | 12,345 |
Tgal
|
$4.10 | |
Water Disposal | $67,596 | 12,345 |
Tgal
|
$5.48 | |
TOTAL YEARLY COSTS | $814,861 | ||||
RECOMMENDED SAVINGS* | $113,561 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,911 | $3,927 | - | - | $3,911 | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $19,066 | - | - | - | - | $19,066 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,898 | $25,297 |
$21,254
425,074
kWh
|
$11,644
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,763 | $3,150 |
$1,763
35,259
kWh
|
- | - | - | |
05 | 2.9114: Use solar heat to make electricty | $15,967 | $218,400 |
$15,242
304,830
kWh
|
$725
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,555 | $1,225 |
$4,555
91,104
kWh
|
- | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $2,964 | $446 |
$1,844
36,880
kWh
|
$1,120
-
kW-mo/yr
|
- | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $4,914 | - |
$4,914
98,287
kWh
|
- | - | - | |
09 | 2.7241: Install outside air damper / economizer on hvac unit | $6,600 | $14,300 |
$6,600
132,000
kWh
|
- | - | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $20,923 | $16,543 |
$20,923
418,464
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $113,561 | $283,288 |
$77,095
1,541,898
kWh
|
$13,489
-
kW-mo/yr
|
$3,911 | $19,066 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs