| Assessment Year | 2022 |
|---|---|
| Principal Product | Construction machinery |
| NAICS | 333120: Construction Machinery Manufacturing |
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 400 |
| Plant Area |
1,085,894
ft2
|
| Annual Production | 40,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $2,246,958 | 17,745,710 |
kWh
|
$0.13 | |
| Electricity Demand | $235,840 | 39,215 |
kW-mo/yr
|
$6.01 | |
| Electricity Fees | $1,962 | - |
|
- | |
| Natural Gas | $706,405 | 72,443 |
MMBtu
|
$9.75 | |
| Waste Disposal Costs | |||||
| Water Usage | $70,409 | 17,825 |
Tgal
|
$3.95 | |
| Water Disposal | $44,919 | 17,825 |
Tgal
|
$2.52 | |
| TOTAL YEARLY COSTS | $3,306,493 | ||||
| RECOMMENDED SAVINGS* | $488,753 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $56,626 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,094 | $6,745 |
$6,094
47,986
kWh
|
- | - | |
| 02 | 2.7261: Install timers and/or thermostats | $22,737 | $3,000 | - | - |
$22,737
-
MMBtu
|
|
| 03 | 2.1134: Eliminate leaks in combustible gas lines | $21,187 | $25,000 | - | - |
$21,187
-
MMBtu
|
|
| 04 | 2.9114: Use solar heat to make electricty | $403,296 | $1,097,180 |
$403,296
3,175,562
kWh
|
- | - | |
| 05 | 2.7211: Clean and maintain refrigerant condensers and towers | $21,682 | $4,810 |
$20,359
160,308
kWh
|
$1,323
-
kW-mo/yr
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,757 | $5,295 |
$13,757
108,326
kWh
|
- | - | |
| TOTAL RECOMMENDED | $488,753 | $1,142,030 |
$443,506
3,492,182
kWh
|
$1,323
-
kW-mo/yr
|
$43,924
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $56,626 | $35,105 |
$34,116
268,634
kWh
|
$1,323
-
kW-mo/yr
|
$21,187
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs