ITAC Assessment: OK1076
ITAC logo
ITAC Assessment: OK1076
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Bread and Buns
NAICS 311812: Commercial Bakeries
SIC 2051: Bread and Other Bakery Products, Except Cookies and Crackers
Sales Range $50
M
to 100
M
# of Employees 268
Plant Area 141,149
ft2
Annual Production 31,200
ton
Production Hrs. Annual 8,760
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $365,981 7,319,622
kWh
Electricity Demand $70,644 15,291
kW-mo/yr
Electricity Fees $8,700 -
Natural Gas $308,300 90,944
MMBtu
Waste Disposal Costs
Water Usage $33,525 6,174
Tgal
Water Disposal $94,191 9,631
Tgal
TOTAL YEARLY COSTS $881,341
RECOMMENDED SAVINGS* $147,319 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $10,234 $20,754 $8,987
179,733
kWh
$1,247
-
kW-mo/yr
- -
02 2.8121: Apply for tax-free status for energy purchases $63,720 - - - - $63,720
03 2.9114: Use solar heat to make electricty $36,196 $540,000 $35,812
716,232
kWh
$384
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,629 $4,215 $11,629
232,578
kWh
- - -
05 2.4221: Install compressor air intakes in coolest locations $6,468 $700 $6,468
114,844
kWh
- - -
06 2.4239: Eliminate or reduce compressed air usage $3,535 - $3,535
70,693
kWh
- - -
07 2.7241: Install outside air damper / economizer on hvac unit $10,090 $2,340 $10,090
201,802
kWh
- - -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,149 $5,702 $4,149
82,986
kWh
- - -
09 2.1233: Analyze flue gas for proper air/fuel ratio $661 $300 - - $661
-
MMBtu
-
10 2.2511: Insulate bare equipment $637 $2,476 - - $637
-
MMBtu
-
TOTAL RECOMMENDED $147,319 $576,487 $80,670
1,598,868
kWh
$1,631
-
kW-mo/yr
$1,298
-
MMBtu
$63,720
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs