Assessment Year 2020
Principal Product Reclaimed Water and Bio-Solids
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $10
M
to 50
M
# of Employees 32
Plant Area 778,550
ft2
Annual Production 4,080,800
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $496,619 7,882,844
kWh
TOTAL YEARLY COSTS $496,619
RECOMMENDED SAVINGS* $256,917 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $256,917

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Primary Raw Material Savings
01 2.4322: Use or replace with energy efficient substitutes $234,675 $218,100 $234,675
3,725,000
kWh
- -
02 2.4133: Use most efficient type of electric motors $18,816 $17,893 $18,816
298,668
kWh
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,426 - $2,968
47,115
kWh
$271 $187
TOTAL RECOMMENDED $256,917 $235,993 $256,459
4,070,783
kWh
$271 $187
TOTAL IMPLEMENTED $256,917 $235,993 $256,459
4,070,783
kWh
$271 $187
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs