| Assessment Year | 2021 |
|---|---|
| Principal Product | Tornado shelters |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3429: Hardware, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 56 |
| Plant Area |
67,200
ft2
|
| Annual Production | 5,880
units
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $142,534 | 1,425,342 |
kWh
|
$0.100 | |
| Electricity Fees | $15,791 | - |
|
- | |
| Natural Gas | $21,731 | 4,829 |
MMBtu
|
$4.50 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,198 | 122 |
Tgal
|
$9.82 | |
| TOTAL YEARLY COSTS | $181,254 | ||||
| RECOMMENDED SAVINGS* | $3,436 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $2,824 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,353 | $8,612 |
$2,353
23,531
kWh
|
|
| 02 | 2.7261: Install timers and/or thermostats | $361 | $1,395 |
$361
3,611
kWh
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $471 | - |
$471
4,713
kWh
|
|
| 04 | 2.6211: Conserve energy by efficient use of vending machines | $251 | $160 |
$251
2,510
kWh
|
|
| TOTAL RECOMMENDED | $3,436 | $10,167 |
$3,436
34,365
kWh
|
||
| TOTAL IMPLEMENTED | $2,824 | $8,612 |
$2,824
28,244
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs