Assessment Year | 2020 |
---|---|
Principal Product | Oil and gas field machinery and equipment |
NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
250,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $368,777 | 3,383,922 |
kWh
|
$0.11 | |
Natural Gas | $133,776 | 19,976 |
MMBtu
|
$6.70 | |
Waste Disposal Costs | |||||
Water Usage | $5,777 | 2,275 |
Tgal
|
$2.54 | |
TOTAL YEARLY COSTS | $508,330 | ||||
RECOMMENDED SAVINGS* | $51,697 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,729 | - |
$3,729
34,215
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $6,084 | $2,187 | - |
$6,084
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,608 | $4,500 |
$5,608
51,450
kWh
|
- | |
04 | 2.7211: Clean and maintain refrigerant condensers and towers | $515 | $540 |
$515
4,718
kWh
|
- | |
05 | 2.7241: Install outside air damper / economizer on hvac unit | $1,437 | $3,178 |
$1,437
13,186
kWh
|
- | |
06 | 2.7261: Install timers and/or thermostats | $34,324 | $2,448 | - |
$34,324
-
MMBtu
|
|
TOTAL RECOMMENDED | $51,697 | $12,853 |
$11,289
103,569
kWh
|
$40,408
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs