Assessment Year 2019
Principal Product Ice coolers, propane lanterns
NAICS 339920: Sporting and Athletic Goods Manufacturing
SIC 3949: Sporting and Athletic Goods, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 1,000
Plant Area 1,300,000
ft2
Annual Production 1,200,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,184,192 54,604,800
kWh
Electricity Demand $1,841,514 99,273
kW-mo/yr
Electricity Fees $148,734 -
Natural Gas $507,683 114,086
MMBtu
TOTAL YEARLY COSTS $4,682,123
RECOMMENDED SAVINGS* $285,782 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $148,049

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $108,355 $105,560 $108,355
2,708,880
kWh
- -
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,601 $16,747 $5,601
140,025
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $107,652 $264,795 $72,926
1,822,965
kWh
$34,726
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $29,328 $2,128 $29,328
733,212
kWh
- -
05 2.4221: Install compressor air intakes in coolest locations $19,941 $2,337 $12,195
304,848
kWh
$7,746
-
kW-mo/yr
-
06 2.7224: Reduce space conditioning during non-working hours $11,069 - $10,233
255,818
kWh
- $836
-
MMBtu
07 2.7241: Install outside air damper / economizer on hvac unit $2,690 - $2,690
67,243
kWh
- -
08 2.1131: Repair faulty insulation in furnaces, boilers, etc $1,146 $1,788 - - $1,146
-
MMBtu
TOTAL RECOMMENDED $285,782 $393,355 $241,328
6,032,991
kWh
$42,472
-
kW-mo/yr
$1,982
-
MMBtu
TOTAL IMPLEMENTED $148,049 $266,923 $112,487
2,811,995
kWh
$34,726
-
kW-mo/yr
$836
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs