Assessment Year | 2019 |
---|---|
Principal Product | Ice coolers, propane lanterns |
NAICS | 339920: Sporting and Athletic Goods Manufacturing |
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 1,000 |
Plant Area |
1,300,000
ft2
|
Annual Production | 1,200,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,184,192 | 54,604,800 |
kWh
|
$0.040 |
Electricity Demand | $1,841,514 | 99,273 |
kW-mo/yr
|
$18.55 |
Electricity Fees | $148,734 | - |
|
- |
Natural Gas | $507,683 | 114,086 |
MMBtu
|
$4.45 |
TOTAL YEARLY COSTS | $4,682,123 | |||
RECOMMENDED SAVINGS* | $285,782 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $148,049 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $108,355 | $105,560 |
$108,355
2,708,880
kWh
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,601 | $16,747 |
$5,601
140,025
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $107,652 | $264,795 |
$72,926
1,822,965
kWh
|
$34,726
-
kW-mo/yr
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $29,328 | $2,128 |
$29,328
733,212
kWh
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $19,941 | $2,337 |
$12,195
304,848
kWh
|
$7,746
-
kW-mo/yr
|
- | |
06 | 2.7224: Reduce space conditioning during non-working hours | $11,069 | - |
$10,233
255,818
kWh
|
- |
$836
-
MMBtu
|
|
07 | 2.7241: Install outside air damper / economizer on hvac unit | $2,690 | - |
$2,690
67,243
kWh
|
- | - | |
08 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $1,146 | $1,788 | - | - |
$1,146
-
MMBtu
|
|
TOTAL RECOMMENDED | $285,782 | $393,355 |
$241,328
6,032,991
kWh
|
$42,472
-
kW-mo/yr
|
$1,982
-
MMBtu
|
||
TOTAL IMPLEMENTED | $148,049 | $266,923 |
$112,487
2,811,995
kWh
|
$34,726
-
kW-mo/yr
|
$836
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs