| Assessment Year | 2017 |
|---|---|
| Principal Product | Foundation repair |
| NAICS | 332312: Fabricated Structural Metal Manufacturing |
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
58,000
ft2
|
| Annual Production | 12,000,000
lb
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $158,584 | 1,366,886 |
kWh
|
$0.12 | |
| Electricity Demand | $73,276 | 10,468 |
kW-mo/yr
|
$7.00 | |
| Natural Gas | $58,921 | 22,262 |
MMBtu
|
$2.65 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,190 | 416 |
Tgal
|
$5.26 | |
| TOTAL YEARLY COSTS | $292,971 | ||||
| RECOMMENDED SAVINGS* | $57,005 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $15,801 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4322: Use or replace with energy efficient substitutes | $3,220 | $14,212 |
$2,380
20,521
kWh
|
$840
-
kW-mo/yr
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $654 | $1,913 | - | - | - |
$654
-
MMBtu
|
|
| 03 | 2.4322: Use or replace with energy efficient substitutes | $199 | $468 |
$199
1,721
kWh
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,254 | $39,396 |
$8,154
70,289
kWh
|
$2,100
-
kW-mo/yr
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,570 | $10,263 |
$3,632
31,320
kWh
|
$938
-
kW-mo/yr
|
- | - | |
| 06 | 2.3212: Optimize plant power factor | $19,022 | $4,357 | - | - | $19,022 | - | |
| 07 | 2.3191: Use demand controller or load shedder | $15,676 | - | - | - | $15,676 | - | |
| 08 | 2.6231: Utilize controls to operate equipment only when needed | $2,433 | $1,608 | - | - | - |
$2,433
-
MMBtu
|
|
| 09 | 2.6232: Install set-back timers | $977 | $1,306 |
$458
3,947
kWh
|
- | - |
$519
-
MMBtu
|
|
| TOTAL RECOMMENDED | $57,005 | $73,523 |
$14,823
127,798
kWh
|
$3,878
-
kW-mo/yr
|
$34,698 |
$3,606
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $15,801 | $50,965 |
$12,244
105,556
kWh
|
$3,038
-
kW-mo/yr
|
- |
$519
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs