Assessment Year | 1996 |
---|---|
Principal Product | Prefabricated Homes |
NAICS |
n/a
|
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 131 |
Plant Area |
100,000
ft2
|
Annual Production | 12,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,926 | 612,544 |
kWh
|
$0.047 |
Electricity Demand | $9,654 | 2,262 |
kW-mo/yr
|
$4.27 |
Natural Gas | $18,729 | 4,464 |
MMBtu
|
$4.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,653 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,082 | $190 | n/a |
$1,562
32,239
kWh
|
$520
-
kW-mo/yr
|
- | - |
02 | 2.7135: Install occupancy sensors | $181 | $200 | n/a |
$181
3,810
kWh
|
- | - | - |
03 | 2.4133: Use most efficient type of electric motors | $135 | $248 | n/a |
$102
1,465
kWh
|
$33
-
kW-mo/yr
|
- | - |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,435 | $545 | n/a |
$5,435
115,182
kWh
|
- | - | - |
05 | 2.4221: Install compressor air intakes in coolest locations | $191 | $800 | n/a |
$191
4,103
kWh
|
- | - | - |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $58 | $640 | n/a |
$58
879
kWh
|
- | - | - |
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $162 | $300 | n/a |
$224
3,517
kWh
|
- |
$(-62.0)
-
MMBtu
|
- |
08 | 2.6218: Turn off equipment when not in use | $639 | $420 | n/a |
$639
13,482
kWh
|
- | - | - |
09 | 3.7137: Replace cloth rags with paper towels | $770 | $475 | n/a | - | - | - | $770 |
TOTAL RECOMMENDED | $9,653 | $3,818 |
$8,392
174,677
kWh
|
$553
-
kW-mo/yr
|
$(-62.0)
-
MMBtu
|
$770 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs