Assessment Year 1996
Principal Product Prefabricated Homes
NAICS
n/a
SIC 2451: Mobile Homes
Sales Range $10
M
to 50
M
# of Employees 131
Plant Area 100,000
ft2
Annual Production 12,000
units
Production Hrs. Annual 2,080
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $28,926 612,544
kWh
Electricity Demand $9,654 2,262
kW-mo/yr
Natural Gas $18,729 4,464
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $9,653 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,082 $190 n/a $1,562
32,239
kWh
$520
-
kW-mo/yr
- -
02 2.7135: Install occupancy sensors $181 $200 n/a $181
3,810
kWh
- - -
03 2.4133: Use most efficient type of electric motors $135 $248 n/a $102
1,465
kWh
$33
-
kW-mo/yr
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,435 $545 n/a $5,435
115,182
kWh
- - -
05 2.4221: Install compressor air intakes in coolest locations $191 $800 n/a $191
4,103
kWh
- - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $58 $640 n/a $58
879
kWh
- - -
07 2.1311: Replace electrically-operated equipment with fossil fuel equipment $162 $300 n/a $224
3,517
kWh
- $(-62.0)
-
MMBtu
-
08 2.6218: Turn off equipment when not in use $639 $420 n/a $639
13,482
kWh
- - -
09 3.7137: Replace cloth rags with paper towels $770 $475 n/a - - - $770
TOTAL RECOMMENDED $9,653 $3,818 $8,392
174,677
kWh
$553
-
kW-mo/yr
$(-62.0)
-
MMBtu
$770
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs