Assessment Year | 2015 |
---|---|
Principal Product | Soft cakes and donuts |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | greater than $500 M |
# of Employees | 500 |
Plant Area |
180,243
ft2
|
Annual Production | 1,050,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,087,700 | 12,635,477 |
kWh
|
$0.086 |
Electricity Demand | $296,783 | 23,094 |
kW-mo/yr
|
$12.85 |
Natural Gas | $500,005 | 93,949 |
MMBtu
|
$5.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $186,869 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,855 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $37,107 | $30,228 |
$30,800
358,144
kWh
|
$6,307
-
kW-mo/yr
|
- | - | |
02 | 2.7135: Install occupancy sensors | $9,764 | $29,490 |
$9,764
113,535
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,801 | $8,234 |
$3,801
44,198
kWh
|
- | - | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $10,151 | $4,000 | - | - |
$10,151
-
MMBtu
|
- | |
05 | 2.2437: Recover waste heat from equipment | $80,375 | $97,500 | - | - |
$80,375
-
MMBtu
|
- | |
06 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $7,464 | $1,177 | - | - |
$7,464
-
MMBtu
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,374 | - |
$5,374
62,491
kWh
|
- | - | - | |
08 | 2.4322: Use or replace with energy efficient substitutes | $2,167 | $2,205 |
$2,167
25,197
kWh
|
- | - | - | |
09 | 2.6232: Install set-back timers | $1,944 | - |
$843
9,798
kWh
|
- |
$1,101
-
MMBtu
|
- | |
10 | 3.7141: Improve cleaning efficiency by maintaining cleaning system | $1,481 | - |
$3,013
35,040
kWh
|
$2,467
-
kW-mo/yr
|
- | $(-4,000.0) | |
11 | 2.2621: Modify refrigeration system to operate at a lower pressure | $27,241 | $2,175 |
$22,615
262,966
kWh
|
$4,626
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $186,869 | $175,009 |
$78,377
911,369
kWh
|
$13,400
-
kW-mo/yr
|
$99,091
-
MMBtu
|
$(-4,000.0) | ||
TOTAL IMPLEMENTED | $6,855 | - |
$8,387
97,531
kWh
|
$2,467
-
kW-mo/yr
|
- | $(-4,000.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs