Assessment Year | 2015 |
---|---|
Principal Product | Commercial Restroom Accessories |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3429: Hardware, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
106,000
ft2
|
Annual Production | 25,000
pieces
|
Production Hrs. Annual | 2,470
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $34,321 | 525,840 |
kWh
|
$0.065 |
Electricity Demand | $21,942 | 2,344 |
kW-mo/yr
|
$9.36 |
Natural Gas | $8,408 | 1,334 |
MMBtu
|
$6.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,394 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,273 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,040 | $1,751 | - | - | - |
$1,040
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,273 | $600 |
$1,273
19,578
kWh
|
- | - | - | |
03 | 2.7134: Use photocell controls | $1,977 | $2,220 |
$1,977
30,415
kWh
|
- | - | - | |
04 | 2.7135: Install occupancy sensors | $276 | $1,202 |
$276
4,234
kWh
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $727 | $2,651 |
$457
7,038
kWh
|
$270
-
kW-mo/yr
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $1,362 | - |
$845
12,998
kWh
|
- | - |
$517
-
MMBtu
|
|
07 | 2.7231: Use radiant heater for spot heating | $3,385 | $15,625 | - | - | - |
$3,385
-
MMBtu
|
|
08 | 2.4322: Use or replace with energy efficient substitutes | $3,154 | $10,516 | - | - | $3,154 | - | |
09 | 2.6218: Turn off equipment when not in use | $201 | $476 |
$201
3,089
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $13,394 | $35,041 |
$5,029
77,352
kWh
|
$270
-
kW-mo/yr
|
$3,154 |
$4,942
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,273 | $600 |
$1,273
19,578
kWh
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs