ITAC Assessment: OK0903
ITAC logo
ITAC Assessment: OK0903
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Industrial winches
NAICS 333923: Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $100
M
to 500
M
# of Employees 300
Plant Area 245,000
ft2
Annual Production 51,277
pieces
Production Hrs. Annual 4,980
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $451,053 5,864,700
kWh
Natural Gas $58,383 9,021
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $158,265 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $118,742

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.6232: Install set-back timers $28,117 $86 $17,164
220,057
kWh
$10,953
-
MMBtu
02 2.7241: Install outside air damper / economizer on hvac unit $96,611 $20,611 $96,611
1,238,599
kWh
-
03 2.7211: Clean and maintain refrigerant condensers and towers $3,411 $228 $3,411
43,737
kWh
-
04 2.7232: Replace existing hvac unit with high efficiency model $6,633 $30,000 $6,633
85,044
kWh
-
05 2.2711: Utilize outside air instead of conditioned air for drying $407 $1,125 $321
4,118
kWh
$86
-
MMBtu
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,717 $11,876 $2,717
34,837
kWh
-
07 2.7135: Install occupancy sensors $2,170 $8,887 $2,170
27,825
kWh
-
08 2.2437: Recover waste heat from equipment $3,490 $2,440 - $3,490
-
MMBtu
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,183 $950 $3,183
40,811
kWh
-
10 2.4322: Use or replace with energy efficient substitutes $8,904 $10,062 $8,904
114,155
kWh
-
11 2.4322: Use or replace with energy efficient substitutes $2,427 $2,112 $2,427
22,283
kWh
-
12 2.2511: Insulate bare equipment $195 $240 $195
2,500
kWh
-
TOTAL RECOMMENDED $158,265 $88,617 $143,737
1,833,966
kWh
$14,529
-
MMBtu
TOTAL IMPLEMENTED $118,742 $61,851 $118,742
1,522,346
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings