Assessment Year | 2015 |
---|---|
Principal Product | Industrial winches |
NAICS | 333923: Overhead Traveling Crane, Hoist, and Monorail System Manufacturing |
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
245,000
ft2
|
Annual Production | 51,277
pieces
|
Production Hrs. Annual | 4,980
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $451,053 | 5,864,700 |
kWh
|
$0.077 |
Natural Gas | $58,383 | 9,021 |
MMBtu
|
$6.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $158,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $118,742 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $28,117 | $86 |
$17,164
220,057
kWh
|
$10,953
-
MMBtu
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $96,611 | $20,611 |
$96,611
1,238,599
kWh
|
- | |
03 | 2.7211: Clean and maintain refrigerant condensers and towers | $3,411 | $228 |
$3,411
43,737
kWh
|
- | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $6,633 | $30,000 |
$6,633
85,044
kWh
|
- | |
05 | 2.2711: Utilize outside air instead of conditioned air for drying | $407 | $1,125 |
$321
4,118
kWh
|
$86
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,717 | $11,876 |
$2,717
34,837
kWh
|
- | |
07 | 2.7135: Install occupancy sensors | $2,170 | $8,887 |
$2,170
27,825
kWh
|
- | |
08 | 2.2437: Recover waste heat from equipment | $3,490 | $2,440 | - |
$3,490
-
MMBtu
|
|
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,183 | $950 |
$3,183
40,811
kWh
|
- | |
10 | 2.4322: Use or replace with energy efficient substitutes | $8,904 | $10,062 |
$8,904
114,155
kWh
|
- | |
11 | 2.4322: Use or replace with energy efficient substitutes | $2,427 | $2,112 |
$2,427
22,283
kWh
|
- | |
12 | 2.2511: Insulate bare equipment | $195 | $240 |
$195
2,500
kWh
|
- | |
TOTAL RECOMMENDED | $158,265 | $88,617 |
$143,737
1,833,966
kWh
|
$14,529
-
MMBtu
|
||
TOTAL IMPLEMENTED | $118,742 | $61,851 |
$118,742
1,522,346
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs