Assessment Year | 2015 |
---|---|
Principal Product | Piping systems |
NAICS | 326122: Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
250,000
ft2
|
Annual Production | 24,000,000
lb
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $669,496 | 12,445,345 |
kWh
|
$0.054 |
Electricity Demand | $186,775 | 27,329 |
kW-mo/yr
|
$6.83 |
Natural Gas | $7,912 | 1,102 |
MMBtu
|
$7.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $116,500 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $94,812 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $4,929 | $24,297 |
$4,929
91,273
kWh
|
- | - | |
02 | 2.7211: Clean and maintain refrigerant condensers and towers | $739 | $468 |
$657
12,169
kWh
|
$82
-
kW-mo/yr
|
- | |
03 | 2.7241: Install outside air damper / economizer on hvac unit | $3,033 | $14,760 |
$3,033
56,175
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,160 | $2,367 |
$1,160
21,475
kWh
|
- | - | |
05 | 2.7231: Use radiant heater for spot heating | $1,358 | $3,750 | - | - |
$1,358
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,781 | $8,612 |
$2,699
49,972
kWh
|
$1,082
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,028 | $3,948 |
$1,028
19,028
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $316 | $329 |
$269
4,975
kWh
|
$47
-
kW-mo/yr
|
- | |
09 | 2.4221: Install compressor air intakes in coolest locations | $441 | $1,262 |
$441
8,163
kWh
|
- | - | |
10 | 2.2437: Recover waste heat from equipment | $524 | $1,220 | - | - |
$524
-
MMBtu
|
|
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $904 | $520 |
$904
16,734
kWh
|
- | - | |
12 | 2.2511: Insulate bare equipment | $44,461 | $58,968 |
$44,461
823,344
kWh
|
- | - | |
13 | 2.4133: Use most efficient type of electric motors | $48,188 | $144,447 |
$48,188
892,367
kWh
|
- | - | |
14 | 2.2136: Install / repair insulation on steam lines | $520 | $1,320 |
$520
9,630
kWh
|
- | - | |
15 | 2.7423: Reduce heat gain by window tinting | $5,118 | $43,272 |
$2,267
41,958
kWh
|
- |
$2,851
-
MMBtu
|
|
TOTAL RECOMMENDED | $116,500 | $309,540 |
$110,556
2,047,263
kWh
|
$1,211
-
kW-mo/yr
|
$4,733
-
MMBtu
|
||
TOTAL IMPLEMENTED | $94,812 | $205,723 |
$94,730
1,754,244
kWh
|
$82
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs