| Assessment Year | 2014 |
|---|---|
| Principal Product | Aerospace Parts Overhauling |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 52 |
| Plant Area |
223,000
ft2
|
| Annual Production | 22
pieces
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,071 | 2,517,600 |
kWh
|
$0.050 |
| Electricity Demand | $87,865 | 9,276 |
kW-mo/yr
|
$9.47 |
| Natural Gas | $47,089 | 8,433 |
MMBtu
|
$5.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,471 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,983 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $706 | $689 | - | - |
$706
-
MMBtu
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $302 | $463 |
$302
6,032
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,983 | $61,440 |
$9,165
183,298
kWh
|
$6,818
-
kW-mo/yr
|
- | |
| 04 | 2.7241: Install outside air damper / economizer on hvac unit | $12,695 | $8,800 |
$12,695
253,900
kWh
|
- | - | |
| 05 | 2.7231: Use radiant heater for spot heating | $10,569 | $37,500 | - | - |
$10,569
-
MMBtu
|
|
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $227 | $798 |
$227
4,554
kWh
|
- | - | |
| 07 | 2.4131: Size electric motors for peak operating efficiency | $1,087 | $3,573 |
$1,087
21,736
kWh
|
- | - | |
| 08 | 2.2511: Insulate bare equipment | $6,439 | $6,993 | - | - |
$6,439
-
MMBtu
|
|
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,385 | $3,468 |
$1,385
27,697
kWh
|
- | - | |
| 10 | 2.2136: Install / repair insulation on steam lines | $78 | $376 |
$29
587
kWh
|
- |
$49
-
MMBtu
|
|
| TOTAL RECOMMENDED | $49,471 | $124,100 |
$24,890
497,804
kWh
|
$6,818
-
kW-mo/yr
|
$17,763
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $15,983 | $61,440 |
$9,165
183,298
kWh
|
$6,818
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs