Assessment Year | 2013 |
---|---|
Principal Product | Fiber Glass, roofing material |
NAICS | 327993: Mineral Wool Manufacturing |
SIC | 3172: Personal Leather Goods, Except Women's Handbags and Purses |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
70,000
ft2
|
Annual Production | 34,000,000
lb
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $489,587 | 13,252,800 |
kWh
|
$0.037 |
Electricity Demand | $216,737 | 25,852 |
kW-mo/yr
|
$8.38 |
Natural Gas | $990,710 | 243,514 |
MMBtu
|
$4.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $324,148 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $150,771 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $33,277 | $58,900 | - | - | $33,277 | - | |
02 | 2.4133: Use most efficient type of electric motors | $655 | $1,128 |
$499
13,514
kWh
|
$156
-
kW-mo/yr
|
- | - | |
03 | 2.2511: Insulate bare equipment | $2,872 | $1,478 | - | - | - |
$2,872
-
MMBtu
|
|
04 | 2.4224: Upgrade controls on compressors | $5,084 | - |
$5,084
137,778
kWh
|
- | - | - | |
05 | 2.4131: Size electric motors for peak operating efficiency | $8,999 | $27,500 |
$5,018
136,000
kWh
|
$3,981
-
kW-mo/yr
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $20,158 | $10,250 |
$16,068
435,460
kWh
|
$4,089
-
kW-mo/yr
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $46,176 | $10,642 |
$34,268
928,676
kWh
|
$11,908
-
kW-mo/yr
|
- | - | |
08 | 2.1113: Reduce combustion air flow to optimum | $127,574 | $25,000 | - | - | - |
$127,574
-
MMBtu
|
|
09 | 3.8126: Use flue gas recuperation to reduce voc | $79,353 | $32,100 | - | - | - |
$79,353
-
MMBtu
|
|
TOTAL RECOMMENDED | $324,148 | $166,998 |
$60,938
1,651,428
kWh
|
$20,134
-
kW-mo/yr
|
$33,277 |
$209,799
-
MMBtu
|
||
TOTAL IMPLEMENTED | $150,771 | $52,992 |
$55,421
1,501,914
kWh
|
$15,997
-
kW-mo/yr
|
- |
$79,353
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs