Assessment Year | 2010 |
---|---|
Principal Product | Refurbished airplane parts |
NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
128,400
ft2
|
Annual Production | 1,980
pieces
|
Production Hrs. Annual | 6,570
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $464,703 | 7,435,200 |
kWh
|
$0.063 |
Natural Gas | $24,600 | 2,817 |
MMBtu
|
$8.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $112,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $99,502 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $10,017 | $6,215 |
$10,017
44,928
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $8,400 | $1,550 |
$8,400
194,400
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $3,477 | $2,599 |
$3,477
62,422
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $1,998 | $13,149 |
$1,998
46,041
kWh
|
- | |
05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $11,414 | $51,875 |
$11,414
263,000
kWh
|
- | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $10,918 | $2,775 |
$10,918
251,917
kWh
|
- | |
07 | 2.3191: Use demand controller or load shedder | $30,411 | $45,000 | - |
$30,411
-
kW-mo/yr
|
|
08 | 2.6212: Turn off equipment during breaks, reduce operating time | $23,800 | $15,600 |
$23,800
548,000
kWh
|
- | |
09 | 2.8121: Apply for tax-free status for energy purchases | $11,625 | - |
$11,625
-
kWh
|
- | |
10 | 2.8112: Combine utility meters | $936 | $175 |
$936
7,457
kWh
|
- | |
TOTAL RECOMMENDED | $112,996 | $138,938 |
$82,585
1,418,165
kWh
|
$30,411
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $99,502 | $130,124 |
$69,091
1,310,815
kWh
|
$30,411
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs