Assessment Year | 2015 |
---|---|
Principal Product | Non-motorized Carts |
NAICS | 332313: Plate Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 116 |
Plant Area |
288,000
ft2
|
Annual Production | 250,000
pieces
|
Production Hrs. Annual | 6,360
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,933 | 2,637,800 |
kWh
|
$0.062 |
Electricity Demand | $20,032 | 7,507 |
kW-mo/yr
|
$2.67 |
Natural Gas | $166,024 | 19,685 |
MMBtu
|
$8.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,341 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,700 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $5,513 | $5,100 |
$5,513
88,914
kWh
|
- | |
02 | 2.5122: Replace high resistance ducts, pipes, and fittings | $5,641 | $18,600 |
$5,641
90,989
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,104 | $1,160 |
$1,946
31,391
kWh
|
$158
-
kW-mo/yr
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $83 | - |
$83
1,342
kWh
|
- | |
TOTAL RECOMMENDED | $13,341 | $24,860 |
$13,183
212,636
kWh
|
$158
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $7,700 | $6,260 |
$7,542
121,647
kWh
|
$158
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs