| Assessment Year | 2010 |
|---|---|
| Principal Product | Metal Processing |
| NAICS | 331221: Rolled Steel Shape Manufacturing |
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 105 |
| Plant Area |
156,000
ft2
|
| Annual Production | 60,000
ton
|
| Production Hrs. Annual | 5,840
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $101,360 | 1,325,360 |
kWh
|
$0.076 |
| Natural Gas | $25,878 | 3,050 |
MMBtu
|
$8.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,518 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,447 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $7,282 | $55,440 | - |
$7,282
-
MMBtu
|
|
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,202 | $3,000 |
$5,202
68,007
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,225 | $56,686 |
$14,225
186,337
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $644 | $5,222 |
$644
8,424
kWh
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,602 | - |
$2,602
34,013
kWh
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $563 | - |
$563
7,352
kWh
|
- | |
| TOTAL RECOMMENDED | $30,518 | $120,348 |
$23,236
304,133
kWh
|
$7,282
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $10,447 | $55,440 |
$3,165
41,365
kWh
|
$7,282
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs