Assessment Year | 2008 |
---|---|
Principal Product | Flat annealed tempered glass |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
150,000
ft2
|
Annual Production | 12,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $598,202 | 9,664,699 |
kWh
|
$0.062 |
Natural Gas | $12,279 | 1,043 |
MMBtu
|
$11.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,465 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $12,463 | $846 |
$12,463
201,348
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $3,125 | $3,460 |
$3,125
50,482
kWh
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,458 | - |
$3,458
55,861
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,066 | - |
$6,066
106,695
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,001 | $2,875 |
$1,001
10,184
kWh
|
|
06 | 2.7135: Install occupancy sensors | $284 | $1,213 |
$284
4,583
kWh
|
|
07 | 4.611: Begin a practice of predictive / preventative maintenance | $2,068 | $200 |
$2,068
-
kWh
|
|
TOTAL RECOMMENDED | $28,465 | $8,594 |
$28,465
429,153
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs