Assessment Year | 2008 |
---|---|
Principal Product | Leather Utility Belts and Tool Bags |
NAICS | 316998: All Other Leather Good and Allied Product Manufacturing |
SIC | 3199: Leather Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
50,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,371 | 970,448 |
kWh
|
$0.078 |
Natural Gas | $29,560 | 2,250 |
MMBtu
|
$13.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,242 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,946 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,231 | $4,120 |
$1,231
67
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $949 | $2,196 |
$949
178
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $399 | $160 |
$399
22
kWh
|
- | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $15 | $21 |
$15
1
kWh
|
- | |
05 | 4.611: Begin a practice of predictive / preventative maintenance | $3,400 | - |
$3,400
-
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,008 | $28,144 |
$1,008
29
kWh
|
- | |
07 | 2.7135: Install occupancy sensors | $960 | $2,000 |
$960
42
kWh
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $482 | $1,000 |
$482
88
kWh
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $258 | $150 |
$258
14
kWh
|
- | |
10 | 2.7221: Lower temperature during the winter season and vice-versa | $1,540 | - | - |
$1,540
-
MMBtu
|
|
TOTAL RECOMMENDED | $10,242 | $37,791 |
$8,702
441
kWh
|
$1,540
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,946 | $36,610 |
$4,406
330
kWh
|
$1,540
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs