Assessment Year | 2007 |
---|---|
Principal Product | Foam for commercial and industrial applications |
NAICS | 337121: Upholstered Household Furniture Manufacturing |
SIC | 2515: Mattresses, Foundations, and Convertible Beds |
Sales Range | $5 M to 10M |
# of Employees | 80 |
Plant Area |
400,000
ft2
|
Annual Production | 2,246,400
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $215,611 | 4,190,000 |
kWh
|
$0.051 |
Electricity Demand | $84,102 | 9,903 |
kW-mo/yr
|
$8.49 |
Natural Gas | $134,769 | 11,949 |
MMBtu
|
$11.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,960 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,165 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $7,165 | $4,559 | - | - | - |
$7,165
-
MMBtu
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $991 | $326 |
$991
12,605
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,756 | - |
$1,756
22,344
kWh
|
- | - | - | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,099 | - | - |
$7,099
-
kW-mo/yr
|
- | - | |
05 | 2.9113: Use solar heat for heat | $14,978 | $138,320 | - | - | - |
$14,978
-
MMBtu
|
|
06 | 2.7145: Install skylights | $22,903 | $139,000 |
$22,903
291,393
kWh
|
- | - | - | |
07 | 4.611: Begin a practice of predictive / preventative maintenance | $2,068 | $200 | - | - | $2,068 | - | |
TOTAL RECOMMENDED | $56,960 | $282,405 |
$25,650
326,342
kWh
|
$7,099
-
kW-mo/yr
|
$2,068 |
$22,143
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,165 | $4,559 | - | - | - |
$7,165
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs