| Assessment Year | 2007 |
|---|---|
| Principal Product | Aerospace structural components |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
150,000
ft2
|
| Annual Production | 70,000
pieces
|
| Production Hrs. Annual | 4,732
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $153,250 | 4,081,527 |
kWh
|
$0.038 |
| Electricity Demand | $88,055 | 10,876 |
kW-mo/yr
|
$8.10 |
| Natural Gas | $58,251 | 6,734 |
MMBtu
|
$8.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $164,435 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7425: Clean or color roof to reduce solar load | $144,120 | $500,000 |
$144,120
1,913,950
kWh
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,666 | $860 |
$9,666
128,367
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $8,334 | $7,480 | - |
$8,334
-
MMBtu
|
|
| 04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $2,042 | $6,800 | - |
$2,042
-
MMBtu
|
|
| 05 | 2.6232: Install set-back timers | $273 | $248 | - |
$273
-
MMBtu
|
|
| TOTAL RECOMMENDED | $164,435 | $515,388 |
$153,786
2,042,317
kWh
|
$10,649
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs