Assessment Year | 2006 |
---|---|
Principal Product | Plastic cups |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
18,000
ft2
|
Annual Production | 4,000,000,000
pieces
|
Production Hrs. Annual | 8,500
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,411 | 1,434,900 |
kWh
|
$0.058 |
Natural Gas | $482,179 | 55,802 |
MMBtu
|
$8.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $103,557 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $588 | $322 | - |
$588
-
MMBtu
|
- | |
02 | 2.2511: Insulate bare equipment | $2,492 | $1,975 | - |
$2,492
-
MMBtu
|
- | |
03 | 2.1212: Operate boilers on high fire setting | $41,858 | $4,100 | - |
$41,858
-
MMBtu
|
- | |
04 | 2.7135: Install occupancy sensors | $380 | $288 |
$380
6,528
kWh
|
- | - | |
05 | 4.821: Pay bills on time to avoid late fees | $13,458 | - | - | - | $13,458 | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,235 | $5,958 |
$3,235
55,678
kWh
|
- | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $7,655 | $2,592 |
$7,655
131,750
kWh
|
- | - | |
08 | 2.7221: Lower temperature during the winter season and vice-versa | $169 | $495 |
$169
4,893
kWh
|
- | - | |
09 | 2.1331: Burn a less expensive grade of fuel | $28,864 | $61,416 | - | - | $28,864 | |
10 | 2.4227: Use compressor air filters | $2,647 | $642 |
$2,647
45,560
kWh
|
- | - | |
11 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,211 | $5,963 |
$2,211
38,046
kWh
|
- | - | |
TOTAL RECOMMENDED | $103,557 | $83,751 |
$16,297
282,455
kWh
|
$44,938
-
MMBtu
|
$42,322 | ||