Assessment Year | 2006 |
---|---|
Principal Product | Automotive Softgoods |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
125,000
ft2
|
Annual Production | 190,000
pieces
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,195 | 1,442,480 |
kWh
|
$0.040 |
Electricity Demand | $52,862 | 6,024 |
kW-mo/yr
|
$8.78 |
Natural Gas | $13,532 | 1,317 |
MMBtu
|
$10.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,073 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,476 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $5,766 | $10,375 |
$2,815
34,293
kWh
|
- |
$2,951
-
MMBtu
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,201 | $5,750 | - |
$4,201
-
kW-mo/yr
|
- | - | |
03 | 2.4234: Cool compressor air intake with heat exchanger | $266 | $521 |
$122
3,016
kWh
|
$144
-
kW-mo/yr
|
- | - | |
04 | 2.4226: Use / purchase optimum sized compressor | $2,193 | $40 |
$1,017
25,176
kWh
|
$1,176
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $407 | $1,300 |
$188
4,655
kWh
|
$219
-
kW-mo/yr
|
- | - | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $2,157 | $15,330 | - | - |
$1,357
-
MMBtu
|
$800 | |
07 | 2.7135: Install occupancy sensors | $1,066 | $1,600 |
$1,066
13,957
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,222 | $67,616 |
$7,847
103,664
kWh
|
- | - | $2,375 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,795 | $8,054 |
$1,613
21,108
kWh
|
- | - | $182 | |
TOTAL RECOMMENDED | $28,073 | $110,586 |
$14,668
205,869
kWh
|
$5,740
-
kW-mo/yr
|
$4,308
-
MMBtu
|
$3,357 | ||
TOTAL IMPLEMENTED | $14,476 | $76,231 |
$10,599
152,964
kWh
|
$1,320
-
kW-mo/yr
|
- | $2,557 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs